As built drawing for 400 kv substation
As built drawing for 400 kv substation





  • Battery and battery charger sizing calculations.
  • Short circuit force calculation for strung bus and rigid tubular bus.
  • Bill of materials for cables, cable trays, racks, earthing, lightning protection and lighting systems.
  • Technical specification of all equipment and materials.
  • as built drawing for 400 kv substation

  • Cable schedule and interconnection diagram for Power and control cables.
  • Control schematics and terminal plans of bay marshalling kiosks.
  • Earthing calculation, layout and earthing details.
  • Survey drawings, Topographical contour layout.
  • Electrical SLD, protections, metering, controls and indications.
  • We have thorough knowhow of designing and preparing drawings for Gas Insulated substations upto 400kV. He wants to Share his experience & Knowledge and help technical enthusiasts to find suitable solutions and updating themselves on various Engineering Topics.Gas Insulated Switchgear Substations are fast gaining popularity in India and many other countries due to contraint of sufficient land for Air insulated outdoor substations. He is Technical Blogger and Familiar with English, Hindi, Gujarati, French languages. He is Freelancer Programmer of Advance Excel and design useful Excel base Electrical Programs as per IS, NEC, IEC,IEEE codes. He has published numbers of Technical Articles in “Electrical Mirror”, “Electrical India”, “Lighting India”,”Smart Energy”, “Industrial Electrix”(Australian Power Publications) Magazines. He is Presently associate with one of the leading business group as a Deputy Manager at Ahmedabad,India. Membership No:F-1264873 ,M-1473586.He has more than 19 years experience in Transmission -Distribution-Electrical Energy theft detection-Electrical Maintenance-Electrical Projects (Planning-Designing-Technical Review-coordination -Execution). He is FIE ,MIE and CEng from Institution of Engineers,India. Jignesh Parmar has completed M.Tech (Power System Control), B.E(Electrical). He wants to Share his experience & Knowledge and help technical enthusiasts to find suitable solutions and updating themselves on various Engineering Topics. Membership No:M-1473586.He has more than 16 years experience in Transmission -Distribution-Electrical Energy theft detection-Electrical Maintenance-Electrical Projects (Planning-Designing-Technical Review-coordination -Execution). He is member of Institution of Engineers (MIE) and CEng,India. Underground telecommunication cable shall be with underground power cable of voltage exceeding 33 kV.Ībout Jignesh.Parmar (B.E,Mtech,MIE,FIE,CEng) Power cable of voltage exceeding 33 kV shall be laid Lying of Telecommunication Cables with Power Cables (>33 kV).

    as built drawing for 400 kv substation

    Safety Clearance from Live Part in Outdoor Substation: The horizontal clearance between the nearer conductor and any part of such buildingĬlearance above ground at the lowest conductor: VoltageĮlsewhere than along or across any streetĬlearance above ground (Add 0.3 Meter for every 33 KV Volts in 5.2 Meter) Line passes above or adjacent to any building or part of a building Line passes adjacent the building a Horizontal clearance Line passes above the building a vertical clearance Line passes adjacent to the building a horizontal clearance from the nearest point Vertical Clearance between Electrical Line and railway tracks.Ĭlearance from Buildings to low, medium & high voltage lines: Voltageįlat roof, open balcony, verandah roof ,When the line passes above the building a vertical clearance from the highest point Permissible Min ground Clearance of Electrical Line:Ĭlearance for Telephone line Crossings Power Line: Minimum clearances between Electrical Lines crossing each other: Aug44 Comments Code: Indian Electricity Rules/ Central Electricity Authority : Right of Way Clearance (As per GETCO Standard):